Model 4200 Series Laminator Manual
Functions and Operation I
Functions and Operation Soft-touch® Control Panel
A. Indicator lamps
Specific lamps are illuminated to indicate the state of one or more of the operating parameters of the laminator.
 |
Temperature Indicator - displays the target operating temperature. Also used to display the current fusion roll temperature when the MEASURE function is selected. |
 |
Roller Speed Indicator - displays the current "running speed" of the lamination rollers |
| COLD |
Indicates that the current chosen pre-set function is COLD (room temperature) lamination. (temp. = RT , speed = 2 ) |
| MEAS |
Indicates that the MEASURE (MEAS) function has been selected and the temperature indicator is displaying the current temperature of the fusion rollers. |
| PREHT |
Indicates that the PRE-HEAT (PREHT) function has been selected. (temp. = 80°C, speed = 2 ) |
| HOT |
Indicates that the HOT function has been selected. (temp. = 90°C, speed = 5) |
| MOUNT |
Indicates that the MOUNTING (MOUNT) function is selected. (temp. = 130°C, speed = 1) |
| CARRI |
Indicates that the MATTING (MOUNT) function is selected. (temp. = 110°C, speed = 2) |
| READY |
Indicates the state of the rollers. Changes state according to the temperature of the rollers as follows:
OFF - the temperature of the fusion rollers is below the set point
BLINKING - the temperature of the fusion rollers is above the set point
ON - the temperature of the fusion rollers is at the set point (+/- 3°C) |